If you’re experiencing issues updating a module to the latest firmware, please follow these steps:

	1. Check Module Hardware Compatibility
	First, verify that your module supports the latest firmware:

		- Older models have firmware versions without the letter 'g' at the beginning. These models can only be updated up to version 1.1.5.
		- Newer models include the letter 'g' in the firmware version (e.g., g1.2.0). These can be updated to the latest available firmware.


	2. Prevent Firmware Update Errors
 	In some cases, firmware updates may fail due to internal memory allocation settings. To resolve this:


		- Connect the module to ToolPro software.
		- Navigate to the Data Logging section.
		- Set the parameters “Number of files” and “File size” to their minimum values.
		- Save the changes.
		- Attempt the firmware update again.
		- Set the parameters “Number of files” and “File size” back to your own settings.